{"product_id":"branick-1000-tower-nitrogen-inflation-system","title":"Branick 1000 Tower Nitrogen Inflation System","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e1000 Tower Nitrogen Inflation System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Branick 1000 Tower Nitrogen Inflation System is designed for moderate- to high-volume tire service facilities that need higher nitrogen output for efficient tire inflation and service. Producing 14.2 CFM of nitrogen with adjustable purity from 95% to 99.5%, the Model 1000 provides a continuous nitrogen supply for shops handling a large number of vehicles. Its 1.9:1 air-to-nitrogen ratio helps maximize compressed-air efficiency during operation.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Model 1000 uses PRISM membrane technology and includes a compressor-saving automatic shut-off to help reduce unnecessary compressor operation. Front-mounted controls, air input and nitrogen output pressure gauges, and an inline nitrogen purity test port make it easy to monitor system performance and verify nitrogen purity. Two pre-filters help support clean operation, while 5 years of free filters are included for convenient maintenance.\u003c\/p\u003e\n\u003cp\u003eA compact 19\" × 19\" footprint allows the tower to provide high output without taking up excessive shop space. The durable all-steel enclosure is designed for demanding service environments, while the unit operates from a standard 110\/120V outlet. Manufactured at Branick's facility in Fargo, North Dakota, the Model 1000 is a practical choice for professional tire shops and automotive service facilities requiring higher nitrogen production.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTower Nitrogen Inflation System 1000 Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAir Input Range: 100–175 PSI\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAir Input: 27.6 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Output: 14.2 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity: Adjustable, 95%–99.5%\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 40°F–150°F\u003c\/li\u003e\n\u003cli\u003eInlet Port (Female): 3\/8\" NPT\u003c\/li\u003e\n\u003cli\u003eOutlet Port (Female): 3\/8\" NPT\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity Port: Yes\u003c\/li\u003e\n\u003cli\u003eAuto Shut-Off: Yes\u003c\/li\u003e\n\u003cli\u003ePre-Filters: 2\u003c\/li\u003e\n\u003cli\u003eN2 Outlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eAir Inlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eWeight: 220 lbs.\u003c\/li\u003e\n\u003cli\u003eDimensions: 19\" D × 19\" W × 72\" H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e1000 Tower Nitrogen Inflation System Special Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for moderate- to high-volume tire service facilities\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e14.2 CFM nitrogen output\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity from 95% to 99.5%\u003c\/li\u003e\n\u003cli\u003e1.9:1 air-to-nitrogen ratio\u003c\/li\u003e\n\u003cli\u003ePRISM membrane technology\u003c\/li\u003e\n\u003cli\u003eCompressor-saving automatic shut-off\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity test port\u003c\/li\u003e\n\u003cli\u003eAir input and nitrogen output pressure gauges\u003c\/li\u003e\n\u003cli\u003eTwo pre-filters\u003c\/li\u003e\n\u003cli\u003e5 years of free filters included\u003c\/li\u003e\n\u003cli\u003eCompact tower design minimizes floor space\u003c\/li\u003e\n\u003cli\u003eStandard 110\/120V electrical connection\u003c\/li\u003e\n\u003cli\u003eDurable all-steel construction\u003c\/li\u003e\n\u003cli\u003eManufactured in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eBranick 1000 M\u003c\/strong\u003e\u003cstrong\u003eanuals\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5200_Installation_and_Operations_Manual.pdf?v=1786586490\" title=\"Branick 5200 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5300_Installation_and_Operations_Manual.pdf?v=1786590024\" title=\"Branick 5700 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5550_Installation_and_Operations_Manual.pdf?v=1786593974\" title=\"Branick 5550 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF_Installation_and_Operations_Manual.pdf?v=1786594838\" title=\"Branick EF Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF-HD_Installation_and_Operations_Manual.pdf?v=1786608529\" title=\"Branick EF-HD Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5025_Installation_and_Operations_Manual.pdf?v=1786616359\" title=\"Branick 5025 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5045_Repair_Parts_Information.pdf?v=1786617375\" title=\"Branick 5045 Repair Parts Information\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5130_Installation_and_Operations_Manual.pdf?v=1786618292\" title=\"Branick 5130 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_130_Mobile_Installation_and_Operations_Manual.pdf?v=1786679611\" title=\"Branick 130 Mobile Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Installation_and_Operations_Manual.pdf?v=1786681068\" title=\"Branick 500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Installation_and_Operations_Manual.pdf?v=1786682630\" target=\"_blank\" title=\"Branick 1000 Tower Installation and Operations Manual\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Installation_and_Operations_Manual.webp?v=1786682663\" alt=\"Branick 1000 Tower Installation and Operations Manual\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Installation_and_Operations_Manual.pdf?v=1786682630\" target=\"_blank\" title=\"Branick 1000 Tower Installation and Operations Manual\" rel=\"noopener\"\u003eBranick 1000 Tower Installation and Operations Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Spec_Sheet.pdf?v=1786682630\" target=\"_blank\" title=\"Branick 1000 Tower Spec Sheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Speec_Sheet.webp?v=1786682663\" alt=\"Branick 1000 Tower Spec Sheet\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Spec_Sheet.pdf?v=1786682630\" target=\"_blank\" title=\"Branick 1000 Tower Spec Sheet\" rel=\"noopener\"\u003eBranick 1000 Tower Spec Sheet\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Branick","offers":[{"title":"Default Title","offer_id":54430141612316,"sku":"1000","price":12799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick1000Tower_1.png?v=1786682854","url":"https:\/\/heavyliftdirect.com\/products\/branick-1000-tower-nitrogen-inflation-system","provider":"HeavyLiftDirect","version":"1.0","type":"link"}