{"product_id":"branick-1500-tower-nitrogen-inflation-system","title":"Branick 1500 Tower Nitrogen Inflation System","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e1500 Tower Nitrogen Inflation System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Branick 1500 Tower Nitrogen Inflation System is the largest generator in the Branick tower lineup, built for high-volume commercial tire shops, fleet operations, and OTR applications. Its triple-membrane design produces up to 21.3 CFM of nitrogen, providing the output needed for facilities servicing multiple bays, commercial truck tires, and other high-demand tire applications. Nitrogen purity is adjustable from 95% to 99.5% to accommodate different service requirements.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Model 1500 uses PRISM membrane technology, which also helps remove moisture from the compressed air supply and supports more consistent nitrogen purity throughout the operating life of the system. An automatic shut-off helps reduce unnecessary compressor use, while front-mounted controls and air input and nitrogen output pressure gauges allow technicians to monitor system operation at a glance. The integrated nitrogen purity test port also provides a convenient way to verify output purity.\u003c\/p\u003e\n\u003cp\u003eBuilt with a durable all-steel enclosure, the Branick 1500 combines high output with a compact 19\" × 19\" footprint to help conserve valuable shop space. The system operates from a standard 110\/120V outlet and includes two pre-filters, with 5 years of free filters included for maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTower Nitrogen Inflation System 1500 Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAir Input Range: 100–175 PSI\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAir Input: 41.4 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Output: 21.3 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity: Adjustable, 95%–99.5%\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 40°F–150°F\u003c\/li\u003e\n\u003cli\u003eInlet Port (Female): 3\/8\" NPT\u003c\/li\u003e\n\u003cli\u003eOutlet Port (Female): 3\/8\" NPT\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity Port: Yes\u003c\/li\u003e\n\u003cli\u003eAuto Shut-Off: Yes\u003c\/li\u003e\n\u003cli\u003ePre-Filters: 2\u003c\/li\u003e\n\u003cli\u003eN2 Outlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eAir Inlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eWeight: 230 lbs.\u003c\/li\u003e\n\u003cli\u003eDimensions: 19\" D × 19\" W × 72\" H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e1500 Tower Nitrogen Inflation System Special Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLargest nitrogen generator in the Branick tower lineup\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for high-volume commercial shops and OTR applications\u003c\/li\u003e\n\u003cli\u003e21.3 CFM nitrogen output\u003c\/li\u003e\n\u003cli\u003eTriple-membrane nitrogen generation system\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity from 95% to 99.5%\u003c\/li\u003e\n\u003cli\u003e1.9:1 air-to-nitrogen ratio\u003c\/li\u003e\n\u003cli\u003ePRISM membrane technology\u003c\/li\u003e\n\u003cli\u003eHelps remove moisture from compressed air\u003c\/li\u003e\n\u003cli\u003eCompressor-saving automatic shut-off\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity test port\u003c\/li\u003e\n\u003cli\u003eAir input and nitrogen output pressure gauges\u003c\/li\u003e\n\u003cli\u003eTwo pre-filters\u003c\/li\u003e\n\u003cli\u003e5 years of free filters included\u003c\/li\u003e\n\u003cli\u003eCompact tower design minimizes floor space\u003c\/li\u003e\n\u003cli\u003eStandard 110\/120V electrical connection\u003c\/li\u003e\n\u003cli\u003eDurable all-steel construction\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eBranick 1500 M\u003c\/strong\u003e\u003cstrong\u003eanuals\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5200_Installation_and_Operations_Manual.pdf?v=1786586490\" title=\"Branick 5200 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5300_Installation_and_Operations_Manual.pdf?v=1786590024\" title=\"Branick 5700 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5550_Installation_and_Operations_Manual.pdf?v=1786593974\" title=\"Branick 5550 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF_Installation_and_Operations_Manual.pdf?v=1786594838\" title=\"Branick EF Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF-HD_Installation_and_Operations_Manual.pdf?v=1786608529\" title=\"Branick EF-HD Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5025_Installation_and_Operations_Manual.pdf?v=1786616359\" title=\"Branick 5025 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5045_Repair_Parts_Information.pdf?v=1786617375\" title=\"Branick 5045 Repair Parts Information\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5130_Installation_and_Operations_Manual.pdf?v=1786618292\" title=\"Branick 5130 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_130_Mobile_Installation_and_Operations_Manual.pdf?v=1786679611\" title=\"Branick 130 Mobile Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Installation_and_Operations_Manual.pdf?v=1786681068\" title=\"Branick 500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Installation_and_Operations_Manual.pdf?v=1786682630\" title=\"Branick 1000 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Installation_and_Operations_Manual.pdf?v=1786683195\" target=\"_blank\" title=\"Branick 1500 Tower Installation and Operations Manual\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Installation_and_Operations_Manual.webp?v=1786683232\" alt=\"Branick 1500 Tower Installation and Operations Manual\" style=\"float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Installation_and_Operations_Manual.pdf?v=1786683195\" target=\"_blank\" title=\"Branick 1500 Tower Installation and Operations Manual\" rel=\"noopener\"\u003eBranick 1500 Tower Installation and Operations Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Spec_Sheet.pdf?v=1786683196\" target=\"_blank\" title=\"Branick 1500 Tower Spec Sheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Spec_Sheet.webp?v=1786683232\" alt=\"Branick 1500 Tower Spec Sheet\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Spec_Sheet.pdf?v=1786683196\" target=\"_blank\" title=\"Branick 1500 Tower Spec Sheet\" rel=\"noopener\"\u003eBranick 1500 Tower Spec Sheet\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Branick","offers":[{"title":"Default Title","offer_id":54430206853404,"sku":"1500","price":18300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower-1.png?v=1786683516","url":"https:\/\/heavyliftdirect.com\/products\/branick-1500-tower-nitrogen-inflation-system","provider":"HeavyLiftDirect","version":"1.0","type":"link"}