{"product_id":"branick-465-mobile-nitrogen-inflation-system","title":"Branick 465 Mobile Nitrogen Inflation System","description":"\u003ch2 class=\"product_title entry-title wd-entities-title\" style=\"text-align: center;\"\u003e\u003cstrong\u003e465 Mobile Nitrogen Inflation System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Branick 465 Mobile Nitrogen Inflation System is designed for shops that need convenient nitrogen tire service without giving up mobility. When technicians need to move between service areas and handle repeated tire fills, the built-in 30-gallon tank provides stored nitrogen for back-to-back service, while the mobile design makes it easy to position the system where it is needed.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe 465 combines PRISM Membrane technology with a hands-free BlockHead automatic tire inflator, allowing technicians to set the desired pressure and let the system handle inflation while they work on other tasks. With 4.0 CFM nitrogen output, adjustable purity from 95% to 99.5%, six conversion ports, and a nitrogen purity test port, it provides a practical setup for passenger and light truck applications. Four hoses with clip chucks are included, with two additional hoses available for converting up to six tires.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMobile Inflation System 465 Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: 465\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Type: Mobile Nitrogen Inflation System\u003c\/li\u003e\n\u003cli\u003eAir Input Range: 100–175 PSI\u003c\/li\u003e\n\u003cli\u003eAir Input: 7.8 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Output: 4.0 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity: Set, 95%–99.5%\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 40°–150°F\u003c\/li\u003e\n\u003cli\u003eInlet Port: 1\/4\" NPT Female\u003c\/li\u003e\n\u003cli\u003eOutlet Port: None\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity Port: Yes\u003c\/li\u003e\n\u003cli\u003eAuto Shut-Off: No\u003c\/li\u003e\n\u003cli\u003ePre-Filters: 2\u003c\/li\u003e\n\u003cli\u003eN2 Outlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eAir Inlet Pressure Gauge: No\u003c\/li\u003e\n\u003cli\u003eInternal Tank: 30 Gallons\u003c\/li\u003e\n\u003cli\u003eHoses: 2 Hooks\u003c\/li\u003e\n\u003cli\u003eInflator Set Pressure Range: 5–145 PSI\u003c\/li\u003e\n\u003cli\u003eInflator Accuracy: ±0.5% Full Scale\u003c\/li\u003e\n\u003cli\u003eDisplay Increments: 1 PSI\u003c\/li\u003e\n\u003cli\u003ePower Supply: 110–130V, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eRechargeable: No\u003c\/li\u003e\n\u003cli\u003eDimensions: 24\" D × 25\" W × 54\" H\u003c\/li\u003e\n\u003cli\u003eWeight: 260 lbs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e465 Mobile Nitrogen Inflation System Special Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePRISM Membrane technology\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e1.9:1 air-to-nitrogen ratio\u003c\/li\u003e\n\u003cli\u003eMobile design for flexible shop use\u003c\/li\u003e\n\u003cli\u003eIntegrated 30-gallon nitrogen tank\u003c\/li\u003e\n\u003cli\u003eHands-free BlockHead automatic tire inflator\u003c\/li\u003e\n\u003cli\u003eConverts up to 6 tires with optional hoses\u003c\/li\u003e\n\u003cli\u003eFour hoses with clip chucks included\u003c\/li\u003e\n\u003cli\u003eNitrogen purity test port\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity from 95%–99.5%\u003c\/li\u003e\n\u003cli\u003eTwo pre-filters\u003c\/li\u003e\n\u003cli\u003eBuilt-in N2 outlet pressure gauge\u003c\/li\u003e\n\u003cli\u003e5 years of free filters\u003c\/li\u003e\n\u003cli\u003eAll-steel construction\u003c\/li\u003e\n\u003cli\u003eNo rechargeable battery required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eBranick 465 M\u003c\/strong\u003e\u003cstrong\u003eanuals\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5200_Installation_and_Operations_Manual.pdf?v=1786586490\" title=\"Branick 5200 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5300_Installation_and_Operations_Manual.pdf?v=1786590024\" title=\"Branick 5700 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5550_Installation_and_Operations_Manual.pdf?v=1786593974\" title=\"Branick 5550 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF_Installation_and_Operations_Manual.pdf?v=1786594838\" title=\"Branick EF Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF-HD_Installation_and_Operations_Manual.pdf?v=1786608529\" title=\"Branick EF-HD Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5025_Installation_and_Operations_Manual.pdf?v=1786616359\" title=\"Branick 5025 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5045_Repair_Parts_Information.pdf?v=1786617375\" title=\"Branick 5045 Repair Parts Information\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5130_Installation_and_Operations_Manual.pdf?v=1786618292\" title=\"Branick 5130 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_130_Mobile_Installation_and_Operations_Manual.pdf?v=1786679611\" title=\"Branick 130 Mobile Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Installation_and_Operations_Manual.pdf?v=1786681068\" title=\"Branick 500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Installation_and_Operations_Manual.pdf?v=1786682630\" title=\"Branick 1000 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Installation_and_Operations_Manual.pdf?v=1786683195\" title=\"Branick 1500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_350_Wall_Mount_Installation_and_Operations_Manual.pdf?v=1786683949\" title=\"Branick 350 Wall Mount Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_450_Wall_Mount_Installation_and_Operations_Manual.pdf?v=1786684562\" title=\"Branick 450 Wall Mount Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_650_Wall_Mount_Installation_and_Operations_Manual.pdf?v=1786700431\" title=\"Branick 650 Wall Mount Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_465_Mobile_Installation_and_Operations_Manual.pdf?v=1786702155\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_465_Mobile_Installation_and_Operations_Manual.webp?v=1786702204\" alt=\"Branick 465 Mobile Installation and Operations Manual\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_465_Mobile_Installation_and_Operations_Manual.pdf?v=1786702155\" title=\"Branick 465 Mobile Installation and Operations Manual\" target=\"_blank\"\u003eBranick 465 Mobile Installation and Operations Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_465_Mobile_Spec_Sheet.pdf?v=1786702155\" target=\"_blank\" title=\"Branick 465 Mobile Spec Sheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_465_Mobile_Spec_Sheet.webp?v=1786702205\" alt=\"Branick 465 Mobile Spec Sheet\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_465_Mobile_Spec_Sheet.pdf?v=1786702155\" target=\"_blank\" title=\"Branick 465 Mobile Spec Sheet\" rel=\"noopener\"\u003eBranick 465 Mobile Spec Sheet\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Branick","offers":[{"title":"Default Title","offer_id":54430961074460,"sku":"465","price":6299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick465Mobile_1.png?v=1786702405","url":"https:\/\/heavyliftdirect.com\/products\/branick-465-mobile-nitrogen-inflation-system","provider":"HeavyLiftDirect","version":"1.0","type":"link"}