{"product_id":"branick-485-mobile-nitrogen-inflation-system","title":"Branick 485 Mobile Nitrogen Inflation System","description":"\u003ch2 class=\"product_title entry-title wd-entities-title\" style=\"text-align: center;\"\u003e\u003cstrong\u003e485 Mobile Nitrogen Inflation System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Branick 485 Mobile Nitrogen Inflation System is built for service operations that need nitrogen generation, tire inflation, and mobility in one system. When technicians need to service vehicles away from a fixed air source, the integrated 30-gallon tank allows passenger vehicle conversions to be performed while the unit remains mobile. Standard hose reels also keep the service area organized and make the system easier to use during repeated tire service.\u003c\/p\u003e\n\u003cp\u003eThe 485 uses PRISM Membrane technology to generate consistent nitrogen while also helping dry the incoming air. With 4.0 CFM nitrogen output, adjustable purity from 95% to 99.5%, automatic shut-off, and a hands-free inflator, it provides the output and control needed for passenger and light truck applications. Four hose reels are included, with six conversion ports available for servicing dual tires or spares, while the rear auxiliary port allows the unit to fill an external storage tank for additional nitrogen capacity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMobile Inflation System 485 Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: 485\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Type: Mobile Nitrogen Inflation System\u003c\/li\u003e\n\u003cli\u003eAir Input Range: 100–175 PSI\u003c\/li\u003e\n\u003cli\u003eAir Input: 7.8 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Output: 4.0 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity: Adjustable, 95%–99.5%\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 40°–150°F\u003c\/li\u003e\n\u003cli\u003eInlet Port: 3\/8\" NPT Female\u003c\/li\u003e\n\u003cli\u003eOutlet Port: 3\/8\" NPT Female\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity Port: Yes\u003c\/li\u003e\n\u003cli\u003eAuto Shut-Off: Yes\u003c\/li\u003e\n\u003cli\u003ePre-Filters: 2\u003c\/li\u003e\n\u003cli\u003eN2 Outlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eAir Inlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eInternal Tank: 30 Gallons\u003c\/li\u003e\n\u003cli\u003eHoses: 4 Reels\u003c\/li\u003e\n\u003cli\u003eInflator Set Pressure Range: 5–145 PSI\u003c\/li\u003e\n\u003cli\u003eInflator Accuracy: ±0.5% Full Scale\u003c\/li\u003e\n\u003cli\u003eDisplay Increments: 1 PSI\u003c\/li\u003e\n\u003cli\u003ePower Supply: 12V DC SLA\u003c\/li\u003e\n\u003cli\u003eRechargeable: Yes\u003c\/li\u003e\n\u003cli\u003eDimensions: 32\" D × 29\" W × 48\" H\u003c\/li\u003e\n\u003cli\u003eWeight: 460 lbs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e485 Mobile Nitrogen Inflation System Special Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePRISM Membrane technology\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e1.9:1 air-to-nitrogen ratio\u003c\/li\u003e\n\u003cli\u003eMobile design with rechargeable 12V DC power\u003c\/li\u003e\n\u003cli\u003eInternal 30-gallon nitrogen tank\u003c\/li\u003e\n\u003cli\u003eHands-free automatic tire inflator\u003c\/li\u003e\n\u003cli\u003eFour integrated hose reels\u003c\/li\u003e\n\u003cli\u003eSix conversion ports for dual tires and spares\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity from 95%–99.5%\u003c\/li\u003e\n\u003cli\u003eNitrogen purity test port\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off\u003c\/li\u003e\n\u003cli\u003eAir inlet and N2 outlet pressure gauges\u003c\/li\u003e\n\u003cli\u003eAuxiliary port for filling external storage tanks\u003c\/li\u003e\n\u003cli\u003eTwo pre-filters\u003c\/li\u003e\n\u003cli\u003e5 years of free filters\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eBranick 485 M\u003c\/strong\u003e\u003cstrong\u003eanuals\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5200_Installation_and_Operations_Manual.pdf?v=1786586490\" title=\"Branick 5200 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5300_Installation_and_Operations_Manual.pdf?v=1786590024\" title=\"Branick 5700 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5550_Installation_and_Operations_Manual.pdf?v=1786593974\" title=\"Branick 5550 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF_Installation_and_Operations_Manual.pdf?v=1786594838\" title=\"Branick EF Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF-HD_Installation_and_Operations_Manual.pdf?v=1786608529\" title=\"Branick EF-HD Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5025_Installation_and_Operations_Manual.pdf?v=1786616359\" title=\"Branick 5025 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5045_Repair_Parts_Information.pdf?v=1786617375\" title=\"Branick 5045 Repair Parts Information\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5130_Installation_and_Operations_Manual.pdf?v=1786618292\" title=\"Branick 5130 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_130_Mobile_Installation_and_Operations_Manual.pdf?v=1786679611\" title=\"Branick 130 Mobile Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Installation_and_Operations_Manual.pdf?v=1786681068\" title=\"Branick 500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1000_Tower_Installation_and_Operations_Manual.pdf?v=1786682630\" title=\"Branick 1000 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_1500_Tower_Installation_and_Operations_Manual.pdf?v=1786683195\" title=\"Branick 1500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_350_Wall_Mount_Installation_and_Operations_Manual.pdf?v=1786683949\" title=\"Branick 350 Wall Mount Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_450_Wall_Mount_Installation_and_Operations_Manual.pdf?v=1786684562\" title=\"Branick 450 Wall Mount Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_650_Wall_Mount_Installation_and_Operations_Manual.pdf?v=1786700431\" title=\"Branick 650 Wall Mount Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_465_Mobile_Installation_and_Operations_Manual.pdf?v=1786702155\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_475_Mobile_Installation_and_Operations_Manual.pdf?v=1786702738\" title=\"Branick 475 Mobile Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_485_Mobile_Installation_and_Operations_Manual.pdf?v=1786703591\" target=\"_blank\" title=\"Branick 485 Mobile Installation and Operations Manual\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_485_Mobile_Installation_and_Operations_Manual.webp?v=1786703623\" alt=\"Branick 485 Mobile Installation and Operations Manual\" style=\"float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_485_Mobile_Installation_and_Operations_Manual.pdf?v=1786703591\" target=\"_blank\" title=\"Branick 485 Mobile Installation and Operations Manual\" rel=\"noopener\"\u003eBranick 485 Mobile Installation and Operations Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_485_Mobile_Spec_Sheet.pdf?v=1786703590\" target=\"_blank\" title=\"Branick 485 Mobile Spec Sheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_485_Mobile_Spec_Sheet.webp?v=1786703623\" alt=\"Branick 485 Mobile Spec Sheet\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_485_Mobile_Spec_Sheet.pdf?v=1786703590\" target=\"_blank\" title=\"Branick 485 Mobile Spec Sheet\" rel=\"noopener\"\u003eBranick 485 Mobile Spec Sheet\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Branick","offers":[{"title":"Default Title","offer_id":54430999183644,"sku":"485","price":8999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick485Mobile_1.png?v=1786703925","url":"https:\/\/heavyliftdirect.com\/products\/branick-485-mobile-nitrogen-inflation-system","provider":"HeavyLiftDirect","version":"1.0","type":"link"}