{"product_id":"branick-500-tower-nitrogen-inflation-system","title":"Branick 500 Tower Nitrogen Inflation System","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e500 Tower Nitrogen Inflation System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Branick 500 Tower Nitrogen Inflation System is designed for moderate- to high-volume tire service facilities that need a dependable source of high-purity nitrogen. With a 7.1 CFM nitrogen output and adjustable purity from 95% to 99.5%, the Model 500 provides a practical solution for shops performing regular nitrogen tire inflation and service. Its 1.9:1 air-to-nitrogen ratio helps make efficient use of compressed air while maintaining consistent nitrogen production.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eBuilt for daily shop use, the Branick 500 features durable PRISM membrane technology and an automatic shut-off that helps reduce unnecessary compressor operation. Front-mounted controls, air input and nitrogen output pressure gauges, and an inline nitrogen purity test port make the system straightforward to monitor and operate. Two pre-filters are included to support proper system performance and simplify routine maintenance.\u003c\/p\u003e\n\u003cp\u003eThe compact tower-style design helps minimize floor space while providing the output needed for busy tire service environments. The unit plugs into a standard 110\/120V outlet and uses a durable all-steel enclosure designed for shop conditions. Manufactured at Branick's facility in Fargo, North Dakota, the Model 500 combines practical operation, adjustable nitrogen purity, and high-output performance in a space-saving system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTower Nitrogen Inflation System 500 Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAir Input Range: 100–175 PSI\u003c\/li\u003e\n\u003cli\u003eAir Input: 13.8 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Output: 7.1 CFM\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity: Adjustable, 95%–99.5%\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 40°F–150°F\u003c\/li\u003e\n\u003cli\u003eInlet Port (Female): 3\/8\" NPT\u003c\/li\u003e\n\u003cli\u003eOutlet Port (Female): 3\/8\" NPT\u003c\/li\u003e\n\u003cli\u003eNitrogen Purity Port: Yes\u003c\/li\u003e\n\u003cli\u003eAuto Shut-Off: Yes\u003c\/li\u003e\n\u003cli\u003ePre-Filters: 2\u003c\/li\u003e\n\u003cli\u003eN2 Outlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eAir Inlet Pressure Gauge: Yes\u003c\/li\u003e\n\u003cli\u003eWeight: 210 lbs.\u003c\/li\u003e\n\u003cli\u003eDimensions: 19\" D × 19\" W × 72\" H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e500 Tower Nitrogen Inflation System Special Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for moderate- to high-volume tire service facilities\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e7.1 CFM nitrogen output\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity from 95% to 99.5%\u003c\/li\u003e\n\u003cli\u003e1.9:1 air-to-nitrogen input\/output ratio\u003c\/li\u003e\n\u003cli\u003ePRISM membrane technology\u003c\/li\u003e\n\u003cli\u003eCompressor-saving automatic shut-off\u003c\/li\u003e\n\u003cli\u003eAdjustable nitrogen purity test port\u003c\/li\u003e\n\u003cli\u003eAir input and nitrogen output pressure gauges\u003c\/li\u003e\n\u003cli\u003eTwo pre-filters\u003c\/li\u003e\n\u003cli\u003eCompact tower design minimizes floor space\u003c\/li\u003e\n\u003cli\u003eStandard 110\/120V electrical connection\u003c\/li\u003e\n\u003cli\u003eDurable all-steel construction\u003c\/li\u003e\n\u003cli\u003eManufactured in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eBranick 500 M\u003c\/strong\u003e\u003cstrong\u003eanuals\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5200_Installation_and_Operations_Manual.pdf?v=1786586490\" title=\"Branick 5200 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5300_Installation_and_Operations_Manual.pdf?v=1786590024\" title=\"Branick 5700 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5550_Installation_and_Operations_Manual.pdf?v=1786593974\" title=\"Branick 5550 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF_Installation_and_Operations_Manual.pdf?v=1786594838\" title=\"Branick EF Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_EF-HD_Installation_and_Operations_Manual.pdf?v=1786608529\" title=\"Branick EF-HD Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5025_Installation_and_Operations_Manual.pdf?v=1786616359\" title=\"Branick 5025 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5045_Repair_Parts_Information.pdf?v=1786617375\" title=\"Branick 5045 Repair Parts Information\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_5130_Installation_and_Operations_Manual.pdf?v=1786618292\" title=\"Branick 5130 Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_130_Mobile_Installation_and_Operations_Manual.pdf?v=1786679611\" title=\"Branick 130 Mobile Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Installation_and_Operations_Manual.pdf?v=1786681068\" title=\"Branick 500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Installation_and_Operations_Manual.webp?v=1786681104\" alt=\"Branick 500 Tower Installation and Operations Manual\" style=\"float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Installation_and_Operations_Manual.pdf?v=1786681068\" title=\"Branick 500 Tower Installation and Operations Manual\" rel=\"noopener\" target=\"_blank\"\u003eBranick 500 Tower Installation and Operations Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Spec_Sheet.pdf?v=1786681068\" target=\"_blank\" title=\"Branick 500 Tower Spec Sheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Spec_Sheet.webp?v=1786681104\" alt=\"Branick 500 Tower Spec Sheet\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick_500_Tower_Spec_Sheet.pdf?v=1786681068\" target=\"_blank\" title=\"Branick 500 Tower Spec Sheet\" rel=\"noopener\"\u003eBranick 500 Tower Spec Sheet\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Branick","offers":[{"title":"Default Title","offer_id":54430118248732,"sku":"500","price":7250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/9502\/1340\/files\/Branick500Tower_1.png?v=1786681377","url":"https:\/\/heavyliftdirect.com\/products\/branick-500-tower-nitrogen-inflation-system","provider":"HeavyLiftDirect","version":"1.0","type":"link"}